CaNaRy - Hydrogen sulphide meter
CaNaRy is designed for pumping stations and other sewage related applications
CaNaRy measures h2s in gaseous form
ACOWA CaNaRy is a unique hydrogen sulfide meter that can measure hydrogen sulfide in gaseous form at concentrations from 0-300ppm, and converts this to a standard 4-20mA signal.
CaNaRy is delivered fully calibrated and ready for installation with a 10m cable and does not need to be calibrated for the entire lifetime of the cell. The lifetime is expected to be 2 years minimum.


CaNaRy´s replaceable measuring cell
CaNaRy is designed in a robust design for installation in pumping stations and other sewage related applications.
CaNaRy is developed on the same principle as our TurTle pressure transmitter, with replaceable measuring cell and standard 4-20mA signal for easy data collection.
- Specifications
- Item number
- Applications
- Documentation
SPECIFICATIONS | |
---|---|
Sensor type | Sure Cell |
Size | L = 235mm, W = 81mm |
Weight | 760g without cable |
Wire connection | Red = Supply, Green = Signal, Black = Screen |
Cable length | 10m, 15m or 30m. |
Free fall drop | 30 cm |
Enclosure class | IP65 |
Supply | 24V DC (10V DC – 28V DC) |
Max. overpressure | 6 bar |
Measuring range | 0-300ppm |
Measurement signal | 4-20 mA |
Resolution | 0.25ppm |
Largest diameter | 81mm |
Sensor housing | Impact resistant PP (Fiberglass 30%) |
Cable housing | AISI 304 |
Cable clamp | TPU |
Cable material | PUR |
Max. operating temperature | +50°C |
Life expectancy | 2 years in one - non-condensing relative humidity |
Operating temperature | -20°C to +50°C |
Certificates | CE |
Item number | Description |
---|---|
1772-2203001 | CaNaRy Hydrogen sulfide measuring cell 0-300ppm / 4-20mA. |
1772-2201010 | Sensor housing for measuring cell with 10m PUR cable. |
1772-2201015 | Sensor housing for measuring cell with 15m PUR cable. |
1772-2201030 | Sensor housing for measuring cell with 30m PUR cable. |
The TurTle level sensor is very flexible and can be used in many different applications, such as:
- Pumping stations
- Sewage treatment plants
- Stormflow
- Level monitoring
- Rivers or streams
- Reservoir and tanks